How our peptides are tested
We do not test our own products. Each certificate names the laboratory that ran the analysis. We source both domestically and internationally, so the laboratory varies by batch. Purity is reported as measured on that lot, never as a catalogue-wide figure.
14 CERTIFICATES ON FILE · 6 LABORATORIES NAMED · 21 PRODUCTS · SEE THE COA LIBRARY
Who tests what
Laboratories do not all run the same tests, so certificates differ. This is what each certificate reports, read from the documents themselves, grouped by the laboratory it names and by who supplied it.
| LABORATORY | CERTIFICATES | WHAT THEY REPORT |
|---|---|---|
| Freedom Diagnostics | BPC-157 10mg, GHK-Cu 50mg, TB-500 10mg, Tesamorelin 10mg, “GLOW” – BPC-157/TB-500/GHK-Cu - 70mg | Purity (HPLC-UV) · Identity by mass (LC-MS) |
| North South Precision Testing China | Epitalon 10mg, KPV - 10mg, Semax 10mg | Purity · Impurities · Heavy metals (Pb, Cd, Hg, As) · Moisture, pH, solubility |
| Vanguard Laboratory | IGF-1 LR3 1mg, Selank 10mg | Purity (HPLC-UV/VIS) · Heavy metals (ICP-MS) · Endotoxin (LAL) · Microbial limits (USP <61>) |
| ILS Laboratories United States | NAD+ 500mg, RTT-3 10mg | Purity (HPLC) · Sterility (PCR) · Endotoxin (USP <85>) · Heavy metals (ICP-MS) · Identity against a reference standard (HPLC-RTM) · Fentanyl screen (immunoassay) |
| Janoshik | MOTS-c 10mg | Purity (HPLC) |
| KMD Analytical | RTT-3 20mg | Purity |
Not every certificate confirms identity. Purity by HPLC measures how much of the sample is the main compound; identity testing (by mass, or against a reference standard) confirms that the main compound is the one on the label. Some certificates also state that the sample information was supplied by the client, which means the laboratory attests to what it was sent and measured, not to where it came from.
How to read a certificate
Using our BPC-157 10mg certificate as the example (open the PDF to follow along).
- SAMPLE NAME AND LOT
- BPC-157 10mg / ABL-BPC-2602The lot is the batch the certificate covers. A certificate describes one lot, and a different lot needs its own.
- CHROMATOGRAPHIC PURITY
- 99.59%The share of the sample that is the main compound, measured by HPLC (high-performance liquid chromatography). It is a measurement of this lot, not a guarantee for every batch.
- METHOD
- HPLC-UV, LC-MSHPLC-UV measures purity. LC-MS measures molecular mass, which confirms the compound's identity.
- UNIT MASS
- 11.88 mg (from the document)The amount of material measured in the vial tested, against a labelled 10 mg.
- DETECTION WAVELENGTH
- 214 nm (from the document)The UV wavelength used to detect peptide bonds in the HPLC run.
- SOURCE LABORATORY
- Freedom DiagnosticsThe laboratory that ran the analysis. We name it on the product page and in the COA library.
- DATE ISSUED
- June 18, 2026When the laboratory issued the certificate.

Compounds without a certificate
7 of 21 products do not have a certificate on file yet: AOD-9604 5mg, CJC-1295 + Ipamorelin 10mg (blend), DSIP - 15mg, FOXO4 10mg, SLU-PP-332 5mg, SS-31 10mg, Thymosin Alpha-1 10mg. Their product pages make no claim about testing, and the COA library lists them as in progress until a certificate arrives.
Questions about a certificate, or need to confirm which lot you received? Contact us with your order number. All products are for laboratory research use only.